足球比分007

<
Home | About Us | News | Products | Solution | Download | Company Qualification | Investment Cooperation | Contact Us
 
DC test products
2 MH-MPJK1 Photovoltaic DC Combiner Box Intelligent Monitoring Device Series
1 MH-PVJK2 photovoltaic DC combiner box intelligent monitoring device series
2 MH-DDC2 Multi-channel Intelligent Current Sensor Series
2 MH-SC1 handheld terminal
2

Leakage current sensor series

AC Test Products
1 MH1034 series three-phase four-wire electrical parameter acquisition module
1 MH1034-2 series two-phase three-phase four-wire electrical parameter acquisition module
1 MH912 series multi-channel single-phase electrical parameter acquisition module series
1 MH-ACJK3 Photovoltaic AC Header Intelligent Monitoring Device Series
1 MH-DDC3 24-channel AC current acquisition module series
1 MH-ACJK3 supporting infrared handset
solution
1 Data room power management system solution
1
1
More ...
Downloads
1 Manual Download
1 Solution download
1 Download
More ...
Service Hotline
1
contact details
Address: International Enterprise, No. 188, Environmental Protection Middle Road, Yuhua District, Changsha City
Center Building 1, Block A 302
Phone: 0731-82739258
Fax: 0731-82739248
Email: cs_mhkj@163.com
MH-DAC3 24-channel AC current acquisition module

3

I. Product Performance Introduction

   MH-DAC3 24-channel AC current sensor acquisition module is a product used in conjunction with our company's MH-ACJK3 AC combiner box intelligent monitoring device. It is mainly used to monitor the incoming branch current of AC combiner box. The working power is provided by MH-ACJK3. The monitored current data of each branch is sent to MH-ACJK3 through the communication line, and then forwarded to the background by MH-ACJK3.

Second, the functional characteristics
● Small size and easy installation.
● The monitoring device directly uses the working power provided by the matching MH-ACJK3.
● 24 line incoming current measurement.
● Configure different current sensors to monitor different current ranges.
● The current sensor is separated from the acquisition module for easy installation.

Third, the technical parameters

Working power

DC3.3V (powered by matching MH-ACJK3)

Measuring rated current

40A 63A 100A 160A optional
(With current transformers of different current specifications)

Current measurement range

0.5%-120% of rated current

Current measurement accuracy

0.5 grade

Normal working temperature

-30 ℃ ~ 70 ℃

Extreme storage temperature

-40 ℃ ~ 85 ℃

Normal working humidity

5% ~ 95% non-condensing

Altitude

≤5000 meters

Fourth, the indicator description
There are three indicators on the acquisition module, the instructions are as follows:
1. RUN Green running indicator. The module is running normally when the module is powered on. This indicator flashes.
2. When TX yellow module sends data to MH-ACJK3, this light flashes.
3. When the RX yellow module receives the data sent by MH-ACJK3, this light flashes.

V. Dimensions and terminal definitions
2
Dimensions: 115 × 90 × 40 (including terminal blocks)
Terminal definition table

Terminal name

Terminal group function

Terminal description

I01 * -I24 *

Current sensor input

Non-inverting terminal of current transformer

Icom

Inverting terminal of current transformer

V +

Connection kit MH-ACJK3

Module working power input
Connect to MH-ACJK3 corresponding terminal

V-

T

Module and serial communication interface
Connect to MH-ACJK3 corresponding terminal

R

Reference wiring diagram

2
Seven, the current transformer selection instructions
The detection accuracy of the module is determined by the module itself and the matching current transformer. It is recommended to use the matching current transformer of our company. If the customer configures the current transformer itself, please choose it according to our detailed requirements. The data reaches 0.5 level accuracy.

Eight, precautions for use

1. Make sure that the working power supply is within the specified range.
2. When connecting external current transformers, please pay attention to the installation direction of the transformers. It is recommended to use the three transformers of a three-phase incoming line as a group to connect the reverse side of the transformers in place and then connect to Icom with a wire Terminal.
3. The use environment should be free of conductive dust and non-corrosive metals and gases that damage insulation.
4. Non-professionals should not disassemble this product.

Nine, instructions

……………………………………………………………………………………………………………………………… ...