DC test products
2 MH-MPJK1 Photovoltaic DC Combiner Box Intelligent Monitoring Device Series
1 MH-PVJK2 photovoltaic DC combiner box intelligent monitoring device series
2 MH-DDC2 Multi-channel Intelligent Current Sensor Series
2 MH-SC1 handheld terminal
2

Leakage current sensor series

AC Test Products
1 MH1034 series three-phase four-wire electrical parameter acquisition module
1 MH1034-2 series two-phase three-phase four-wire electrical parameter acquisition module
1 MH912 series multi-channel single-phase electrical parameter acquisition module series
1 MH-ACJK3 Photovoltaic AC Header Intelligent Monitoring Device Series
1 MH-DDC3 24-channel AC current acquisition module series
1 MH-ACJK3 supporting infrared handset
solution
1 Data room power management system solution
1
1
More ...
Downloads
1 Manual Download
1 Solution download
1 Download
More ...
Service Hotline
1
contact details
Address: International Enterprise, No. 188, Environmental Protection Middle Road, Yuhua District, Changsha City
Center Building 1, Block A 302
Phone: 0731-82739258
Fax: 0731-82739248
Email: cs_mhkj@163.com
MH-PVJK2 photovoltaic DC combiner box intelligent monitoring device (supports 24 channels 1500V system)

1

1

I. Product Performance Introduction

The MH-PVJK2 photovoltaic combiner box intelligent monitoring device is a newly developed multifunctional, low power, fully intelligent combiner box monitoring unit developed by our company. It has the following functions in one device:
1. Innovative "monitoring host + multi-channel intelligent current sensor" mode, small size and easy installation
2. The monitoring host directly uses photovoltaic power as the working power and provides working power to the intelligent current sensor.
3. The intelligent current sensor adopts an integrated package, which has extremely high reliability.
4.The intelligent current sensor comes with a data interface to connect to the monitoring host
5.Measure photovoltaic voltage
6.Measure multiple direct currents and multiple total currents
7.Measure multi-channel DC power and multi-channel total power
8. One-way temperature measurement for measuring the temperature in the box (optional)
9, two dry contact switch input, can monitor the operation status of the lightning arrester and the main switch separately
10. Isolated RS485 interface is used for remote data communication and supports MODBUS-RTU protocol
11.The infrared data port can be conveniently used for field data inspection and parameter setting
12, built-in comprehensive protection alarm function, not only the various alarm parameters programmable settings, and each alarm function can be individually set to close or enable, convenient field application
MH-PVJK2 monitoring device is small in size and easy to install. The spacing of the smart sensor is a standard spacing of 18mm, which is the same width as a small circuit breaker, which is convenient for wiring. The use of integrated multi-channel DC sensors not only improves the reliability of the product, but also reduces the wiring in many combiner boxes. The combiner box using this device can be made more neat and beautiful, and more secure.

Model description

  1. Monitoring device host model: MH-PVJK2
  2. Intelligent current sensor selection:

1

Third, the outline size and terminal definition diagram of the monitoring host

                 1

1
Terminal definition table

Terminal name

Terminal group function

Terminal description

PV +

Photovoltaic high voltage input

Photovoltaic high voltage anode

PV-

Photovoltaic high voltage anode

V +

Smart current sensor connection

Connect the smart sensor V + terminal

V-

Connect smart sensor V-terminal

A

Connect smart sensor A / TX terminal

B

Connect the smart sensor B / RX terminal

T1

temperature

Connect to temperature sensor

T2

Connect the other end of the temperature sensor

DI1

Digital input 1 (dry contact)

For connecting lightning arresters

DI2

Digital input 2 (dry contact)

For connecting circuit breakers

A

Data upload 485 interface

RS485 A

B

RS485 B

GND

RS485 common

1

Ground terminal

Connect the ground wire (good ground)

  Four, intelligent current sensor appearance size and terminal definition diagram
1

Dimensions of 16 channels: 340 × 38 × 15
1

12-way overall dimensions: 268 × 38 × 15
1

8-way overall dimensions: 196 × 38 × 15
1

Terminal definition table

Terminal name

Terminal group function

Terminal description

V +

Multi-channel DC sensor connection

Connect to monitoring host V + terminal

V-

Connect monitoring host V-terminal

A / TX

Connect the monitoring host A terminal

B / RX

Connect the monitoring host B terminal

Note: The two groups of terminals on the left and right are through, either side can be connected.

  Five, monitoring host technical parameters

Photovoltaic voltage input

DC 300V ~ 1500V

Voltage measurement range

DC 300V ~ 1500V

Voltage measurement accuracy

0.5 grade

Temperature measurement range

-40 ℃ ~ 100 ℃

Temperature measurement accuracy

± 1 ℃

Switch input

Passive dry contact input

Infrared interface

38KHz modulation, 2 meters range, 15 ° declination

Normal working temperature

-30 ℃ ~ 70 ℃

Shell temperature rise

Bottom: <10K ??? Front: <5K (at 70 ° C ambient temperature)

Extreme storage temperature

-40 ℃ ~ 85 ℃

Normal working humidity

5% ~ 95% non-condensing

Altitude

≤4000 meters

Safety isolation voltage

Between PV input and secondary ??? 4400VAC? 60 seconds
Between PV input and case ground ??? 4400VAC? 60 seconds
Data upload interface and main circuit: 1500VAC 60 seconds

Impact withstand voltage

12KV (1.2 / 50μS)

Smart current sensor interface
External power supply

Voltage: DC 5V
Maximum load current: 200mA

Data upload interface

Standard RS-485 interface
Address: 1-240 can be set
Baud rate: 2400bps, 4800bps, 9600bps can be set
Factory setting is 9600bps
Data format: 10 bits without parity (1,8,1.n)
11-bit odd parity (1,8,1.odd)
11-bit even parity (1,8,1, even) can be set
Factory setting is 11-bit even parity
Number of supported nodes: 128

Technical parameters of multi-channel DC sensors

Working power input

DC 4.5-5.5V current <20mA

Measuring rated current

DC 15A

Measuring current range

DC -5A ~ + 15A

Current measurement accuracy

? 0.5 level

Data output interface

RS-485 9600bps 8-bit without parity

Data communication protocol

MODBUS RTU

Normal working temperature

-30 ℃ ~ 80 ℃

Extreme storage temperature

-40 ℃ ~ 85 ℃

Safety isolation voltage

5000VAC between the tested photovoltaic wire and the case ground and terminal

Overload capacity

Instant (<200ms) 5 times rated current without damage

Seven, current sensor connection instructions
The intelligent sensor interface of the MH-PVJK2 monitoring host can support 1-2 current sensors, and the host software supports up to 24 channels of current monitoring. If a current sensor is connected, the current sensor address is set to 1; if two current sensors are connected, the current sensor address should be set to 1 and 2 respectively; the order of the 24 channels is the current sensor number with the address 1 first, and the current sensor 1 It is defined as 12-channel sensors, which are numbered 1-12; then the current sensors with address 2 are numbered 13-24.
Both current sensors are based on the RS485 bus and can be cascaded. The sensors are designed with two identical 4-wire interfaces on the left and right, which can be easily cascaded.

Eight, the description of the monitoring host indicator
There are four indicators on the monitoring host, the instructions are as follows:
1. RUN The green running indicator light, the host is powered on and running normally, this light flashes; when the host is not connected to the smart sensor, this light is always off. Flashing; the flashing status of this light can be used to determine whether the smart sensor is connected properly.
2. ALM red alarm indicator light. When the alarm is activated and an alarm occurs, this light is on.
3. TX yellow host data upload and send indicator. When the monitoring host receives the command correctly and sends data to the background, this light is on.
4. RX yellow As long as there is data transmission on the RS485 bus, this light will be on. You can judge the bus activity based on the flashing of the RX light.

Nine, monitoring host MODBUS-RTU communication protocol description
Special Note: This product supports reading up to 40 registers at a time.
1. The serial communication of this device fully complies with the standard MODBUS-RTU protocol. The data format, hardware timing and data frame structure fully comply with the MODBUS protocol. As long as we use our configuration special software or infrared handset to configure the device address and communication baud Rate and data format for fast and error-free communication.
2. This device supports the functional field codes in the MODBUS protocol:

function code

meaning

Features

03H

Read register

Read measurement data, read all setting parameters

10H

Write register

Set communication address, baud rate, data format, various alarm parameters, etc.

3. Detailed function code
Function code 03H: read register, read preset parameters
Data definition: See register data comparison table
Example 1: Read 485 serial communication parameters:
Command: 01 03 00 41 00 01 CRC
Address function code start address register number CRC check
Response: 01 03 02 02 02 CRC
Address function code byte number parameter CRC check
The readout parameter is 0202H , which indicates that the baud rate of the measurement and control device is 9600 bps, and the data format is 1,8,1 even parity.

Function code 03H: read register, read measurement data and parameters
Data definition: See register data comparison table
Example 2: Read the first current data:
Command: 01 03 01 08 00 01 CRC 8 bytes
Address function code start address register number CRC check
Response: 01 03 02 00 20 CRC 7 bytes
Address Function Code Bytes Current Data CRC Check
Read the first current data: 0.32A (32/100)

Function code 10H: write register
Data definition: See register data comparison table.
Example 5.Preset alarm parameters (set the overvoltage alarm threshold of No. 1 measurement and control device to 800V)
Command: 01? 10?? 0042 0001? 02? 1f40? CRC
Address function code start address register number of bytes? 800.0V CRC check
Response: 01 10 0042 0001 CRC
Address function code start address register number CRC check

Ten, device parameter setting
1. The device address and serial port settings are registers 0040H and 0041H. See the attached data sheet for data definition.
2. By setting the register with address 0060H, you can choose to enable or disable various alarms.
3. Each alarm parameter has been set to the optimal value when it leaves the factory, and generally does not need to be modified. For special circumstances, please refer to the attached data sheet.
4. After the alarm conditions are not met, the device will automatically exit the alarm. If the alarm conditions cannot be removed immediately. To cancel the alarm output, you can prohibit the corresponding alarm items or all alarms, and then re-enable the alarm after the alarm conditions are removed.
5. The channel setting register is a total of 24 registers from 0048H-005FH. For unused channels, the corresponding register can be set to 0 to close the channel. The channels set to closed are not included in the calculation of the average value, and the channel is not included Call the police.
6. The current abnormal alarm is mainly used to monitor the poor performance of the battery panel. When the average current is greater than the set value (default value 3A), the current abnormal alarm can be activated. The alarm rule is: when the current of a certain channel is lower than half of the average value or 1.5 times higher than the average value and held for five minutes continuously, an alarm is generated.

Eleven precautions for use
1. Make sure that the working power supply is within the specified range.
2. Make sure that the communication interface is connected to a standard RS485 network. It is recommended to use a shielded twisted-pair cable of 120 ohms for external RS485 network cables.
3. The G terminal of the data upload interface is the communication power ground. Generally, no connection is required. If the interference is particularly serious, each node can be connected by a separate wire. Grounding can interfere with communication.
4. The earth terminal on the monitoring host is a lightning overvoltage bleeder terminal. Please be sure to connect it during installation.
5. The use environment should be free of conductive dust and non-corrosive metals and gases that damage insulation.
6. Non-professionals should not disassemble this product.
7. If the RS485 network cable of the connected device has an outdoor part, please do lightning protection treatment of the network cable.

12.Instructions
……………………………………………………………………………………………………………………………… ...